OBC-2024-MANDATORY O. Reg. 163/24 | The 2024 Ontario Building Code (O. Reg. 163/24) replaced the 2012 Building Code effective January 1, 2025, and became mandatory for all permit applications submitted on or after April 1, 2025. | Government of Ontario: 2024 Ontario Building Code→ | 2026-09-02 |
OBC-NBC-HARMONIZE O. Reg. 163/24 & NBC 2020 | The 2024 Ontario Building Code harmonizes provincial provisions with the National Building Code of Canada 2020 secondary suite provisions, eliminating approximately 1,730 provincial variations. | Government of Ontario / McMillan LLP Regulatory Transition→ | 2026-09-02 |
CEILING-BASEMENT-MIN Division B, Table 11.5.1.1.C., Compliance Alternative 102 | A basement secondary dwelling unit requires a minimum clear ceiling height of 1.95 m (6' 4¾") over the entire required floor area, including the complete route to the exit. | Government of Ontario: Add a second unit to your house→ | 2026-09-02 |
CEILING-ATTIC-MIN Division B, Table 11.5.1.1.C., Compliance Alternative 102 | For second units located in an attic, at least 50% of the required floor area must have a clear ceiling height of 2.03 m (6' 8"). Areas with ceiling height below 1.4 m (4' 7") are excluded from floor area calculations. | Government of Ontario: Add a second unit to your house→ | 2026-09-02 |
EGRESS-BASEMENT-WINDOW Division B, Table 11.5.1.1.C., Compliance Alternative 136 | Basement and ground-floor secondary suite bedrooms require an escape/egress window with a minimum clear open area of 0.38 m² (4.1 sq ft), no openable dimension less than 460 mm (18"), and a sill height no higher than 900 mm (2' 11") above the floor. | Government of Ontario: Add a second unit to your house→ | 2026-09-02 |
EGRESS-UPPER-WINDOW Division B, Table 11.5.1.1.C., Compliance Alternative 136 | Upper-floor secondary suite bedrooms require an escape window with a minimum height of 1,060 mm (3' 6"), a minimum width of 560 mm (1' 10"), and a sill height not exceeding 900 mm (2' 11") above the floor. | Government of Ontario: Add a second unit to your house→ | 2026-09-02 |
FIRE-SEPARATION-STANDARD Division B, Table 11.5.1.1.C., Compliance Alternatives 147, 152, 153 | Fire separation between dwelling units, and between dwelling units and common areas, must provide a minimum 30-minute fire-resistance rating. | Government of Ontario: Add a second unit to your house→ | 2026-09-02 |
FIRE-SEPARATION-REDUCED-ALARMS Division B, Table 11.5.1.1.C., Compliance Alternatives 147, 152, 153 | The fire separation rating may be reduced to 15 minutes if the whole house is equipped with interconnected smoke alarms. A standard assembly example uses 38×89 mm wood studs, 13 mm drywall on both sides, and fibre insulation. | Government of Ontario: Add a second unit to your house→ | 2026-09-02 |
ALARMS-SMOKE-CAN-ULC Division B, Subsection 9.10.19 | Smoke alarms must meet CAN/ULC S531, feature visual flashing-light activation (strobe), and be installed on every level of the home, outside sleeping areas, in each bedroom of the second unit, and in common hallways or utility areas. | Government of Ontario: Add a second unit to your house→ | 2026-09-02 |
ALARMS-CARBON-MONOXIDE Division B, Articles 9.33.4.1 & 9.33.4.2, Compliance Alternative 197 | Carbon monoxide alarms are mandatory where the furnace burns natural gas, propane or similar fuels, or where an attached garage exists. Alarms must be situated near sleeping areas in the second unit and in the furnace room if enclosed. | Government of Ontario: Add a second unit to your house→ | 2026-09-02 |
NATURAL-LIGHT-GLAZING Division B, Article 9.7.2.3, Compliance Alternative 107 | Natural light glazing must equal at least 5% of the floor area in living and dining rooms, and 2.5% of the floor area in bedrooms. Glazing is not mandatory in kitchens, bathrooms, or laundry areas. | Government of Ontario: Add a second unit to your house→ | 2026-09-02 |
ELECTRICAL-ESA-PERMIT Ontario Electrical Safety Code / ESA Notification | A separate electrical permit is required for secondary unit wiring, and a final Electrical Safety Authority (ESA) inspection certificate is mandatory before occupancy (1-877-ESA-SAFE / 372-7233). | Government of Ontario: Add a second unit to your house→ | 2026-09-02 |
OTTAWA-ZONING-2026-50 Ottawa By-law No. 2026-50 | City of Ottawa Council enacted comprehensive Zoning By-law 2026-50 on March 11, 2026, establishing new Neighbourhood Zones N1 through N6 (with N5 and N6 governing mid- and high-rise contexts). | City of Ottawa: Zoning By-law No. 2026-50→ | 2026-09-02 |
OTTAWA-DUAL-BYLAW-RULE Ottawa Transition Provisions, By-law 2026-50 | Applications deemed complete on or after March 11, 2026 must comply with BOTH By-law 2008-250 AND By-law 2026-50: 'the most restrictive provisions from both by-laws applying'. Applications complete prior to March 11, 2026 are evaluated under By-law 2008-250 only. | City of Ottawa: Zoning By-law No. 2026-50→ | 2026-09-02 |
OTTAWA-APPEALS-STATUS OLT Oral Decision (July 2, 2026) & Council Memo (July 7, 2026) | On July 2, 2026, the Ontario Land Tribunal (OLT) issued an oral decision bringing un-appealed portions of By-law 2026-50 into effect retroactive to March 11, 2026. Twenty-five appeals remain active; the July 7, 2026 Council memo remains the authority on sections not in force. | City of Ottawa: Update on Status of Appeals, July 7 2026 Memo to Council→ | 2026-09-02 |
OTTAWA-PERMIT-MANDATORY Building Code Act, 1992, s. 8 & 10 | A building permit is legally mandatory before proceeding with an additional dwelling unit. Even when minimal physical construction is needed, a formal 'Change of Use' permit must be reviewed for Building Code and applicable law compliance. | City of Ottawa: Adding an apartment (additional dwelling units)→ | 2026-09-02 |
OTTAWA-MUNICIPAL-UNITS-COUNT City of Ottawa ADU Provisions / Planning Act s. 16(3) | Properties connected to City of Ottawa municipal water and wastewater services are permitted up to two additional dwelling units (e.g., two basement or internal suites, or one interior suite plus a detached coach house). | City of Ottawa: Adding an apartment (additional dwelling units)→ | 2026-09-02 |
OTTAWA-SEPTIC-UNITS-COUNT Ottawa Septic Office / Part 8 OBC | Properties on private services (well and septic) are restricted to a maximum of one additional dwelling unit or coach house, and reserve sewage disposal capacity must be formally confirmed by the Ottawa Septic Office. | City of Ottawa: Adding an apartment (additional dwelling units)→ | 2026-09-02 |
OTTAWA-BCIN-DESIGNER-REQ Building Code Act, 1992 / O. Reg. 163/24 Qualifications | Where two additional dwelling units are added within the principal building, drawings must be created and sealed by a designer registered with a Building Code Identification Number (BCIN). A homeowner may take design responsibility for one ADU where no other exists, or for a coach house. | City of Ottawa: Adding an apartment (additional dwelling units)→ | 2026-09-02 |
OTTAWA-GROUND-FLOOR-ACCESS City of Ottawa Zoning & Part 9 OBC | A new secondary dwelling unit must be situated on the same lot and provide separate access on the ground floor, unless specific building and fire codes allow an approved alternate means of egress. | City of Ottawa: Adding an apartment (additional dwelling units)→ | 2026-09-02 |
OTTAWA-NO-PARKING-MANDATE City of Ottawa Zoning By-laws (2008-250 & 2026-50) | No additional motor vehicle parking space is required for a secondary dwelling unit in Ottawa. If a parking space is provided, it cannot be situated in the front yard; tandem parking in the existing driveway is expressly permitted. | City of Ottawa: Adding an apartment (additional dwelling units)→ | 2026-09-02 |
OTTAWA-15-DAY-FIRST-REVIEW City of Ottawa Enhanced Service Level (Council Approved) | The City of Ottawa operates under a Council-approved enhanced service level target of 15 business days for first review of complete residential secondary dwelling unit permit applications. | City of Ottawa: Adding an apartment (additional dwelling units)→ | 2026-09-02 |
OTTAWA-48-HR-INSPECTION City of Ottawa Inspection Standards | Mandatory municipal construction inspections must be booked at least 48 hours in advance, and approved City-stamped permit drawings must be physically present on site for the inspector. | City of Ottawa: Adding an apartment (additional dwelling units)→ | 2026-09-02 |
OTTAWA-PRE-2005-EXCEPTION Ottawa By-law Historical Amalgamation Standards | Secondary dwelling units were permitted prior to 2005 in Cumberland-Urban, Gloucester, Nepean-Urban, Osgoode, Goulbourn, and West Carleton. Units established before 2005 in those areas must comply with the Building Code and Fire Code. | City of Ottawa: Adding an apartment (additional dwelling units)→ | 2026-09-02 |
FINANCIAL-TAX-INSURANCE-NOTICES Assessment Act / Income Tax Act / Insurance Bureau of Canada | Creating a legal secondary suite can trigger an MPAC property tax reassessment; gross rental income is taxable under the federal Income Tax Act; and homeowners must notify their property insurance provider, as homeowner policies typically require endorsement or adjustment for secondary rental units. | City of Ottawa & Government of Ontario Advisory Notices→ | 2026-09-02 |
FIRE-CODE-RETROFIT-9-8 O. Reg. 213/07, Part 9, Section 9.8 | Ontario Fire Code (O. Reg. 213/07) Section 9.8 (Retrofit: Two Unit Residential Occupancies) governs two-unit homes established on or before July 14, 1994, with stacked or shared-egress suites, covering containment, means of escape, alarms, and electrical reviews. | Ontario Fire Code (O. Reg. 213/07) / CanLII→ | 2026-09-02 |