Renovation guide · Bathrooms

Planning an accessible bathroom for ageing in place

A bathroom that works at 80 is mostly decided at 60: what’s behind the walls, how you step into the shower and how hot the water can get.

6 min readUpdated By SS Carpentry and Renovations

Plan of an accessible bathroom: a clear turning circle in the middle of the floor, a curbless shower with a linear drain, a toilet near a side wall with grab bars beside and behind it, a vanity with open knee space, a pocket door, and backing inside every wall.

Key takeaways

  • Falls are the leading cause of injury hospitalizations for Canadians over 65, and about half happen at home.
  • Ontario’s Building Code asks for wall reinforcement in a house’s main bathroom, so grab bars can be added later. If yours has none, add it while the walls are open.
  • A curbless shower at least 1,525 mm square, with a linear drain, works for the most people.
  • Shower and tub water is capped at 49°C by the valve, even though an electric tank stores it at 60°C or more.

Why plan a bathroom for later?

Because falls happen at home, and the bathroom is one of the likeliest places. The Public Health Agency of Canada reports that falls are the leading cause of injury hospitalizations among Canadians 65 and older, about 87% of them, and that about half of those falls happen at home. CMHC’s accessibility guide calls the bathroom the site of many accidents and falls, and the bathtub one of the most common places to fall in a house.

Most of what makes a bathroom safe later is easy while the walls and floor are open, and hard once they’re finished: blocking in a wall before it’s tiled, a shower floor framed without a step, a door wide enough for a walker. That’s why it belongs in the plan of any bathroom renovation, not only one for someone who needs it today.

What does the Building Code already ask for?

Less than you might think, plus one thing most people don’t know about. The Code’s barrier-free design rules don’t apply to detached, semi-detached and row houses. But it does set two rules for houses that matter here:

Ontario 2024 Building Code requirements that make a house bathroom safer later (Division B)
ArticleWhat it requires
9.5.2.4Where the main bathroom is framed with wood or steel studs, reinforcement in the walls so grab bars can be added later, beside and behind the toilet, in the shower and at the tub.
7.2.10.7Water from a shower head or into a tub no hotter than 49°C, through a pressure-balanced or thermostatic valve that also limits sudden temperature swings.

The second matters more than it sounds. The Code sets an electric water heater to store water at 60°C or more. The valve at the shower is what brings that down to 49°C, and it also limits sudden swings in temperature: thermal shock, in the Code’s words.

What goes behind the walls?

A grab bar is only as strong as what it’s screwed into. CMHC says grab bars must go into studs or reinforced walls, and cites a standard of at least 133 kg of support; the Code’s figure is 1.3 kN. Not drywall alone.

Side view of a toilet against a wall, with an L-shaped grab bar on the wall beside it: the horizontal part 750 millimetres above the floor, the vertical part 150 millimetres in front of the toilet, and reinforcement in the wall behind both.1234
  • 1: Reinforcement in the wall: the Code asks for it in a house’s main bathroom, so grab bars can be added later
  • 2: L-shaped bar, each leg 750 mm, the horizontal part 750 mm above the floor
  • 3: The vertical part 150 mm in front of the toilet
  • 4: Bars 30 to 40 mm thick, 38 to 50 mm off the wall, fixed to hold 1.3 kN (about 130 kg)
The grab bar beside a toilet, as the Code’s barrier-free rules place it, and the reinforcement behind it. The bar behind the toilet is at least 600 mm long, 840 to 920 mm up, or 150 mm above the tank.

CMHC’s simplest answer is ¾″ plywood on every bathroom wall, floor to ceiling in the shower. Then the bars can go wherever the person using them needs them, now or in ten years, without opening a tiled wall. It’s the same idea as the ¾″ Baltic birch backing we fix to the studs behind a wall-mounted TV.

Curbless shower or tub?

For the most people, a curbless shower. CMHC calls a custom, wheel-in shower the design that suits the most users, at least 1,525 × 1,525 mm (60 × 60″). A typical prefabricated stall is 915 × 1,525 mm with a curb, and even a 25 mm curb means most wheelchair users have to transfer in.

  • A linear drain to one side lets the floor slope one way, evenly, which is easier to move on in a wheelchair.
  • Controls no higher than 1,220 mm and a hand-held shower on a hose at least 1,525 mm long.
  • A collapsible water dam at the entrance: 25 mm high, flattens when stepped on or rolled over.

A curbless floor still needs its waterproofing done right; our guide to waterproofing a shower covers it. Keeping a tub? CMHC lists a cut-out in the side of an existing tub as an inexpensive way to make it safer, and notes that in a walk-in tub you stay inside while it fills and drains.

How much room does it need?

Plan of an accessible bathroom: a clear turning circle in the middle of the floor, a curbless shower with a linear drain, a toilet near a side wall with grab bars beside and behind it, a vanity with open knee space, a pocket door, and backing inside every wall.ABCDEF
  • A: Clear space to turn around: at least 1,525 × 1,525 mm (60 × 60″), more for a power chair or scooter
  • B: Curbless shower, at least 1,525 × 1,525 mm, with a linear drain to one side
  • C: Toilet centred 455 to 485 mm (18 to 19″) from the side wall, with grab bars beside and behind it
  • D: Vanity with knee space underneath: 760 mm high, 785 mm wide, 610 mm deep
  • E: Door with at least 860 mm (34″) of clear width when open; a pocket door keeps the swing out of the room
  • F: ¾″ plywood backing on the walls, so grab bars can go wherever they’re needed
One way to lay out a bathroom for later, using CMHC’s dimensions. The turning space can overlap a curbless shower floor.
Space and fixtures for an accessible bathroom, from CMHC’s accessibility guides
WhatCMHC guidance
Turning spaceAt least 1,525 × 1,525 mm (60 × 60″); 1,830 × 1,830 mm for a power chair or scooter
At each fixtureA clear space of 760 × 1,220 mm (30 × 48″) in front of or beside it
DoorAt least 860 mm (34″) clear when open, usually a 915 mm door; a pocket or sliding door where a swing won’t fit
ToiletCentred 455 to 485 mm from the side wall; seat 405 to 455 mm high
SinkKnee space 760 mm high, 785 wide and 610 deep, hot pipes insulated or moved back; a single-lever faucet

What helps without a full renovation?

  • A raised toilet seat. CMHC calls it a cost-effective fix that needs no renovation work.
  • Grab bars into studs. Where there’s no reinforcement, a stud is the fixing point; the position follows the stud, not the person.
  • A hand-held shower and a lever faucet. CMHC recommends both for flexibility and ease of use.
  • A lever on the door. CMHC suggests lever handles for everyone, from arthritic hands to full arms.

Is there money for it, and does it need a permit?

The federal Home Accessibility Tax Credit covers up to $20,000 a year of eligible work for someone 65 or older, or eligible for the disability tax credit. The City of Ottawa’s Ontario Renovates programme also funds accessibility changes for lower-income households; our guide to renovation tax credits and rebates in Ottawa has who qualifies and how to apply.

Moving the toilet or the shower drain is a plumbing alteration, which needs a building permit; replacing fixtures where they are is the City’s exception. Our guide to which renovation work needs a permit in Ottawa has the City’s lists.

A bathroom typically takes 3 to 4 weeks on site with us. If you’re planning a bathroom renovation as part of renovating a home in Ottawa for the years ahead, say so at the estimate, and the blocking goes in while the walls are open.

Guidance only, not a design or code ruling. An occupational therapist can assess the needs of the person who’ll use the bathroom; the Ontario Building Code and each product’s instructions set what the work must meet.

Questions

Quick answers

Not the bars themselves. It requires reinforcement in the walls of a house’s main bathroom, where it’s framed with wood or steel studs, so grab bars can be added later beside and behind the toilet, in the shower and at the tub.

CMHC recommends a clear turning space of at least 1,525 × 1,525 mm (60 × 60″), or 1,830 mm square for a power chair, plus 760 × 1,220 mm of clear space in front of or beside each fixture, and a door with at least 860 mm of clear width.

Ontario’s Building Code caps water from a shower head or into a bathtub at 49°C, through a pressure-balanced or thermostatic valve. The water heater itself stores water hotter, at 60°C or more for an electric tank.

In the Code’s barrier-free rules, the bar beside the toilet is L-shaped, with its horizontal part 750 mm above the floor and its vertical part 150 mm in front of the toilet. The bar behind it is at least 600 mm long, 840 to 920 mm up.

Sources

Every figure, with its source

No figure on this page is published from memory. Each one links to the official page it was read from, on the date shown. Guide last reviewed October 31, 2026.

Sourced claims used in this guide
RefClaimPrimary sourceRead
OBC-9.5.2.1
Div. B 9.5.2.1.(1) and (2)
Every building shall be designed in conformance with Section 3.8 (barrier-free design), except that its requirements need not be provided for detached houses, semi-detached houses, houses with a secondary suite, duplexes, triplexes, row houses and small boarding or rooming houses.Ontario 2024 Building Code Compendium (O. Reg. 163/24) (opens in a new tab)
OBC-9.5.2.4
Div. B 9.5.2.4.(1)
If wood wall studs or sheet steel wall studs enclose the main bathroom in a dwelling unit, reinforcement shall be installed to permit the future installation of grab bars: for a water closet, the side-wall grab bar of 3.8.3.8.(3)(a) and the rear-wall grab bar of 3.8.3.8.(3)(c); for a shower, a grab bar described in 3.8.3.13.(2)(g); and for a bathtub, a grab bar described in 3.8.3.13.(7)(e).Ontario 2024 Building Code Compendium (O. Reg. 163/24) (opens in a new tab)
OBC-3.8.3.8
Div. B 3.8.3.8.(5)–(7)
The side-wall grab bar is continuous L-shaped with 750 mm horizontal and vertical components, wall mounted with the horizontal component 750 mm above the finished floor and the vertical component 150 mm in front of the water closet. The rear-wall grab bar is at least 600 mm long, mounted horizontally 840 to 920 mm above the floor, or 150 mm above the tank where there is one. Grab bars resist a load of at least 1.3 kN, are 30 to 40 mm in diameter, sit 38 to 50 mm from the wall and have a slip-resistant surface.Ontario 2024 Building Code Compendium (O. Reg. 163/24) (opens in a new tab)
OBC-3.8.3.13
Div. B 3.8.3.13.(2)(g) and (7)(e)
In a barrier-free shower, one grab bar is 1 000 mm long, vertical on the side wall, with its lower end 600 to 650 mm above the floor; one is L-shaped on the wall opposite the entrance, with a 1 000 mm horizontal component 750 to 870 mm above the floor. For a bathtub, three grab bars at least 1 200 mm long, two vertical at each end and one horizontal along its length, mounted 80 to 280 mm above the rim.Ontario 2024 Building Code Compendium (O. Reg. 163/24) (opens in a new tab)
OBC-7.2.10.7
Div. B 7.2.10.7.(1), (4); 7.2.10.7B.(1), (4)
Water supplied to shower heads or bathtubs shall be controlled by an automatic compensating valve, and the temperature of water discharging from a shower head or into a bathtub shall not exceed 49°C. Valves supplying fixed shower heads shall be individually pressure-balanced or thermostatic-mixing valves, capable of limiting thermal shock and limited to 49°C.Ontario 2024 Building Code Compendium (O. Reg. 163/24) (opens in a new tab)
OBC-9.31.6.1A
Div. B 9.31.6.1A.(1) and (2)
Service hot water is supplied at 45°C to 60°C, and an electric storage-type water heater has a minimum set storage temperature of 60°C.Ontario 2024 Building Code Compendium (O. Reg. 163/24) (opens in a new tab)
PHAC-FALLSIn Canada, falls are the leading cause of injury-related hospitalizations and injury deaths among people aged 65 or older; falls were about 87% of injury hospitalizations in that age group from 2008/2009 to 2019/2020. About half (52%) of fall-related hospitalizations were for falls in a household residence.Public Health Agency of Canada: Surveillance report on falls among older adults in Canada (opens in a new tab)
CMHC-SPACEProvide manoeuvring space of 760 × 1,220 mm in front of or beside all fixtures. A minimum manoeuvring space of 1,525 × 1,525 mm within the bathroom lets users turn around and approach every element; for power wheelchairs or scooters, 1,830 × 1,830 mm. The bathroom is the site of many accidents and falls; bathtubs are one of the most common locations for falls in the home.CMHC: Renovating for Accessibility, Bathrooms (2021) (opens in a new tab)
CMHC-SHOWERThe custom-built, curbless, wheel-in shower accommodates the most people; it should be at least 1,525 × 1,525 mm. Most prefabricated shower units are 915 × 1,525 mm with a curb, and even a 25 mm curb means most wheelchair users must transfer. A linear trench drain lets the floor be evenly sloped; the drain should be to the side. Controls at most 1,220 mm high; a hand-held hose at least 1,525 mm long. A 25 mm flexible water dam at the entrance flattens when stepped on or wheeled over. Reframing the floor for a wet room is more difficult and expensive in a renovation.CMHC: Renovating for Accessibility, Bathrooms (2021) (opens in a new tab)
CMHC-GRAB-BARSGrab bars must be installed into studs or reinforced walls; CSA B651 requires a minimum support of 133 kg. Reinforcing the walls around tubs and toilets during construction avoids removing tile and walls later; 19 mm (¾″) plywood on all bathroom walls is the most universal solution, and floor-to-ceiling backing on shower walls allows bars wherever they are needed. A horizontal tub bar sits 180 to 280 mm above the rim; a vertical bar beside the tub is highly recommended.CMHC: Renovating for Accessibility, Bathrooms (2021) (opens in a new tab)
CMHC-FIXTURESCSA B651 gives toilet seat heights of 405 to 455 mm; a raised seat can be added to an existing toilet without renovation work. The toilet centre line should be 455 to 485 mm from the wall. An accessible sink needs knee space 760 mm high, 785 mm wide and 610 mm deep, with hot pipes insulated, shielded or offset. A single-lever or motion-sensor faucet is most convenient. An existing tub can be converted with a cut-out in its side wall; in a walk-in tub, you stay in while it fills and drains.CMHC: Renovating for Accessibility, Bathrooms (2021) (opens in a new tab)
CMHC-DOORSDoors should provide at least 860 mm (34 in.) of clear passage width when open; a 915 mm (36 in.) door usually does. Offset hinges on an 865 or 810 mm door maximize clear width. Where hinged doors don’t fit, consider sliding, pocket, bifold or accordion doors. Lever handles suit everyone.CMHC: Accessible Housing by Design, Living Spaces (2016) (opens in a new tab)
CRA-HATCThe Home Accessibility Tax Credit (line 31285) covers up to $20,000 a year in eligible expenses for a qualifying individual: 65 or older at the end of the year, or eligible for the disability tax credit. The renovation must let the qualifying individual gain access to, or be mobile or functional within, the dwelling.CRA: Line 31285, Home accessibility expenses (opens in a new tab)
PERMIT-REQUIRED-LISTThe City's own list of common projects that require a building permit includes: adding or removing walls (creating different room sizes or uses); enlarging or relocating a window or door; new windows where there were none before; plumbing alterations, additions or extensions (except replacing existing fixtures); and structural repairs or alterations. The City says to contact its Client Service Centre or 3-1-1 if your project is not on the list or you are unsure.City of Ottawa: Building permit projects (opens in a new tab)